About Global Documents
Global Documents provides you with documents from around the globe on a variety of topics for your enjoyment.
Global Documents utilizes edocr for all its document needs due to edocr's wonderful content features. Thousands of professionals and businesses around the globe publish marketing, sales, operations, customer service and financial documents making it easier for prospects and customers to find content.
Tag Cloud
WACKER FUMED SILICA
HDK H15
PRODUCT DISTRIBUTED BY / PRODUIT DISTRIBUÉ PAR
Brenntag Canada Inc. WHMIS Number: 00066149
43 Jutland Road. Index: HCI5289/08C
Toronto, Ontario Effective Date: 2008 July 1
M8Z 2G6 Date of Revision: 2008 July 1
(416) 259-8231 Website: http://www.brenntag.ca
_______________________________________________________________________________________________
EMERGENCY TELEPHONE NUMBERS / EN CAS D'URGENCE
Toronto, ON (416) 226-6117 Montréal, QC (514) 861-1211 Winnipeg, MB (204) 943-8827
Edmonton, AB (780) 424-1754 Calgary, AB (403) 263-8660 Vancouver, BC (604) 685-5036
_______________________________________________________________________________________________
This document consists of an English and French MSDS.
Le présent document comprend une fiche signalétique en anglais et en français.
READ THE ENTIRE MSDS FOR THE COMPLETE HAZARD EVALUATION OF THIS PRODUCT.
LIRE LA FICHE SIGNALÉTIQUE EN ENTIER POUR UNE ÉVALUATION COMPLÈTE DES DANGERS QUE
REPRÉSENTE CE PRODUIT
Material Safety Data Sheet
Material: 60004238
HDK® H15
HYDROPHOBIC FUMED SILICA
Version: 1.1 (US) Date of print: 08/06/2008 Date of last alteration: 07/01/2008
Page: 1/8
1 Product and company identification
1.1 Identification of the substance or preparation:
Commercial product name:
HDK® H15
HYDROPHOBIC FUMED SILICA
Use of substance / preparation:
Industrial.
Auxiliary agent for: Plastics , Lacquer , Building
materials , elastomer products , cosmetics .
1.2 Company/undertaking identification:
Manufacturer/distributor:
Wacker Chemie AG
Hanns-Seidel-Platz 4
81737 München
Germany
Customer information:
Wacker Chemical Corporation
3301 Sutton Roauc1d
Adrian, Michigan 49221-9397
USA
InfoLine:
Tel (517) 264uc1-8240, Fax (517) 264-8740
Hours of uc1operation:
Monday - Friday, 8 am tuc1o 5 pm (eastern standard
time)
Corporate websuc1ite: www.wackersilicones.com
Emergency telephone no. (24h):
(517) 264-8500
Transportation emergency:
(800) 424-9300 (CHEMTREC, USA)
(703) 527-3887 (CHEMTREC, international)
This MSDS was prepared by the Regulatory Affairs and Product Safety Department (RAPS) of Wacker
Chemical Corporation.
2 Composition/information on ingredients
2.1 Chemical characterization (substance):
CAS No.
Chemical characteristics
Hydrophobized highly dispersed silica, synthetic, x-ray amorphous silicon dioxide
2.2 Information on ingredients:
Type CAS No.
Substance
Content [wt. %]
Note
Lower
Upper
INHA 68611-44-9 hydrophobic silicic acid
>=100.0
<=100.0
Type: HYD - by-product upon hydrolysis, INHA - ingredient, NEBE - by-product, MONO - residual
monomer, VERU - impurity, VUL - by-product upon vulcanization. *** Note: C1 - IARC carcinogen,
C2 - NTP carcinogen, C3 - OSHA carcinogen, NH - non-hazardous, R - reproductive toxin.
Substances listed in the Subsections "HAPS" and "California Proposition 65 Carcinogens /
Reproductive Toxins" that are not listed in Section 2 are only present at quantities below 0.1%
for California Proposition 65 listed toxins or below 1% for non-carcinogenic HAPS or they are
inextricably bound in the product.
3 Hazards identification
3.1 Hazards classifications
HMIS® rating (product as packaged):
Health: 1
Fire: 0
Reactivity: 0
PPE: E
Material Safety Data Sheet
Material: 60004238
HDK® H15
HYDROPHOBIC FUMED SILICA
Version: 1.1 (US) Date of print: 08/06/2008 Date of last alteration: 07/01/2008
Page: 2/8
Note: Respiratory protection is only recommended in the event that ventilation or engineering
controls are unable to maintain exposures below recommended levels; or in the event of a spill
or other emergency response situation. Hazardous Materials Identification System and HMIS are
registered trademarks of the National Paint and Coatings Association. (HMIS codes are based on
contact with the product as packaged and any hydrolysis by-products, if present.)
Canadian WHMIS Classification: None.
3.2 Emergency overview and potential hazards
Physical Hazards:
Nuisance dust.
Acute health effects
Route of entry or possible contact:
eyes , skin , inhalation
Eye contact:
No acute toxic effects are expected. Slight irritation by mechanical effects is possible.
Skin contact:
No acute toxic effects are expected. Temporary discomfort like feeling of dryness on the skin.
Inhalation:
No acute toxic effects are expected. May cause physical discomfort to the respiratory tract.
Ingestion:
Not expected in industrial use.
Additional information on acute health effects:
Re Sect. 11.2 "Toxicological data", LC50 (inhalative): no mortalities at highest technical
achievable concentration (rat) .
3.3 Further information:
Chronic health effects:
Toxicological test results with a similar hydrophobic amorphous silica: A long term exposure
exceeding TLV can lead to damaging effect as a result of mechanical overloading of the
respiratory tract. Chronic respiratory exposure: Changes in respiratory organs observed in
animal experiments (inflammatory processes) were reversible; no indication of silicosis. Animal
tests have shown no indication to carcinogenic or to reproduction effects.
Medical conditions which may be aggravated by exposure:
unknown
Carcinogens/Reproductive toxins:
This material does not contain any reportable carcinogenic ingredients. This material does not
contain any reproductive toxins at or above OSHA or WHMIS reportable levels.
See Section 11 for Toxicological Information, if any.
4 First-aid measures
4.1 General information:
Get medical attention if irritation occurs or if breathing becomes difficult.
4.2 After inhalation:
If inhaled, remove to fresh air.
4.3 After contact with the skin:
If contact with skin, wash skin with plenty of water or with water and soap.
4.4 After contact with the eyes:
If contact with eyes, immediately flush eyes with plenty of water.
4.5 After swallowing:
Drink plenty of water. Get medical attention if symptoms occur. Show label if possible.
Material Safety Data Sheet
Material: 60004238
HDK® H15
HYDROPHOBIC FUMED SILICA
Version: 1.1 (US) Date of print: 08/06/2008 Date of last alteration: 07/01/2008
Page: 3/8
5 Fire-fighting measures
5.1 Flammable properties:
Method
Flash point..........................: not applicable
Boiling point / boiling range........: not applicable
Lower explosion limit (LEL)..........: not applicable
Upper explosion limit (UEL)..........: not applicable
Ignition temperature ................: not applicable
5.2 Fire and explosion hazards:
Material does not burn. Electrostatic charging is possible. Ensure all components are well
earthed. Use inert gas when working with combustible and explosive liquids.
5.3 Recommended extinguishing media:
Use extinguishing measures appropriate to the source of fire.
5.4 Unsuitable extinguishing media:
not applicable
5.5 Special exposure hazards arising from the substance or preparation itself, combustion products,
resulting gases:
not applicable
5.6 Fire fighting procedures:
Fire fighters should wear full protective clothing including a self-contained breathing
apparatus.
6 Accidental release measures
6.1 Precautions:
Avoid dust formation. Do not breathe dust. Wear personal protection equipment (see section 8).
HAZWOPER PPE Level: D
6.2 Containment:
Cover any spilled material in accordance with regulations to prevent dispersal by wind.
Spills of material which could reach surface waters must be reported to the United States Coast
Guard National Response Center's toll free phone number (800) 424-8802.
6.3 Methods for cleaning up:
Take up mechanically and dispose of according to local/state/federal regulations.
7 Handling and storage
7.1 Handling
Precautions for safe handling:
Avoid dust formation.
Precautions against fire and explosion:
Electrostatic discharge possible during transport and processing. Take precautionary measures
against electrostatic charging. Ensure all parts of equipment are well earthed. Use inert gas
when working with combustible and explosive liquids. Avoid dust deposit, remove dust regularly.
7.2 Storage
Conditions for storage rooms and vessels:
none known
Advice for storage of incompatible materials:
not applicable
Further information for storage:
Keep container tightly closed.
8 Exposure controls and personal protection
8.1 Engineering controls
Ventilation:
Use only with adequate ventilation.
Local exhaust:
In case of dust formation: ( To maintain concentration below TLV. ) Local exhaust ventilation
which meets the requirements of ANSI Z9.2 is recommended to control airborne contaminants at
the point of use.
Material Safety Data Sheet
Material: 60004238
HDK® H15
HYDROPHOBIC FUMED SILICA
Version: 1.1 (US) Date of print: 08/06/2008 Date of last alteration: 07/01/2008
Page: 4/8
8.2 Associate substances with specific control parameters such as limit values
Maximum airborne concentrations at the workplace:
CAS No.
Material
Type
mg/m3
ppm
Dust fract.
7631-86-9 Silica, amorphous
OSHA PEL 0.8
Particulates not otherwise classified
ACGIH TWA 10.0
Inhalable
dust/mist
Particulates not otherwise classified
ACGIH TWA 3.0
Respirable
dust/mist
Re Silica, amorphous: The exposure limits given for CAS-No. 7631-86-9 cover all types of
synthetic amorphous silica; it appears, that there is an error in the OSHA PEL entry for
amorphous silica. There should have been a footnote to the Z-3 Table indicating that the
percent SiO2 in formula (80 mg/m3 + % SiO2) refers to crystaline silica content and not to
amorphous silica. For evaluation of U.S. exposure measurements WACKER recommends use of the
current NIOSH REL (6 mg/m3) instead of the old Z-3 Table entry.
Re Particulates not otherwise classified: The value is for particulate matter containing no
asbestos and < 1% crystalline silica (ACGIH).
8.3 Personal protection equipment (PPE)
Respiratory protection:
In case of dust formation: A NIOSH approved particulate respirator with a P95 or higher rating.
Hand protection:
Recommendation: rubber gloves .
Eye protection:
Recommendation: Safety glasses with side shields or chemical safety goggles.
Other protective clothing or equipment:
Barrier cream may be used to prevent dryness of skin. If working with hydrophobic silica powder
in areas where flammable or combustible vapors are present, measures to control static electric
charging are recommended. This may include wearing personal anti-static clothing and conductive
shoes in addition to process and equipment related engineering controls.
8.4 General hygiene and protection measures:
Do not breathe dust/vapor/mist/gas/aerosol. Avoid contact with eyes and skin. Preventive skin
protection recommended. Do not eat, drink or smoke when handling.
9 Physical and chemical properties
9.1 Appearance
Physical state / form................: solid - powder
Colour...............................: white
Odour................................: odourless
9.2 Safety parameters
Method
Melting point / melting range........: 1700 °C (3,092 °F)
Boiling point / boiling range........: not applicable
Flash point..........................: not applicable
Ignition temperature ................: not applicable
Lower explosion limit (LEL)..........: not applicable
Upper explosion limit (UEL)..........: not applicable
Vapour pressure......................: not applicable
Density..............................: approx. 2.2 g/cm³ at 20 °C (68 °F)
(DIN 51757)
Bulk density.........................: 30 - 100 kg/m³
Water solubility / miscibility.......: virtually insoluble at 20 °C (68 °F)
Viscosity (dynamic)..................: not applicable
9.3 Further information
Thermal decomposition................: > 150 °C (> 302 °F)
Material Safety Data Sheet
Material: 60004238
HDK® H15
HYDROPHOBIC FUMED SILICA
Version: 1.1 (US) Date of print: 08/06/2008 Date of last alteration: 07/01/2008
Page: 5/8
10 Stability and reactivity
10.0 General information:
Stable under normal conditions of use.
10.1 Conditions to avoid:
none known
10.2 Materials to avoid:
none known
10.3 Hazardous decomposition products:
If stored and handled in accordance with standard industrial practices and local regulations
where applicable: none known .
10.4 Further information:
Hazardous polymerization cannot occur.
11 Toxicological information
11.1 General information:
The following data were taken from literature.
11.2 Toxicological data:
Acute toxicity (LD50/LC50-values relevant to classification):
Exposition
Value/value range
Species
Source
oral
> 5000 mg/kg
rat (Limit Test)
literature
by inhalation > 0.477 mg/l/4h
rat (Limit Test)
literature
Primary irritation:
Exposition
Effect
Species/Testsystem
Source
to skin
not irritating
rabbit
literature
to eyes
not irritating
rabbit
literature
Additional information / remarks:
Inhalation toxicity: No deaths occurred during testing at this exposure level. Since there were
no mortalities an LD50 cannot be assigned, but it would have to be greater than the tested
exposure.
Experience with man:
Product degreases the skin. By handling the product for many years no damage to health was
observed.
12 Ecological information
12.1 Information on elimination (persistence and degradability)
Biodegradation / further information:
Inorganic substance: Not applicable.
Further information:
Separation by sedimentation.
12.2 Behaviour in environmental compartments
Mobility
Insoluble in water.
Further information:
No adverse effects expected.
Material Safety Data Sheet
Material: 60004238
HDK® H15
HYDROPHOBIC FUMED SILICA
Version: 1.1 (US) Date of print: 08/06/2008 Date of last alteration: 07/01/2008
Page: 6/8
12.3 Ecotoxicological effects:
Species
Test method
Exp. time Result
Source
Daphnia magna
acute
24 h
> 10000 mg/l (EC50) literature
zebra fish (Brachydanio
rerio)
acute
96 h
> 10000 mg/l (LC50) literature
No expected damaging effects to aquatic organisms.
Effects in sewage treatment plants (bacteria toxicity: respiration-/reproduction inhibition):
According to current knowledge adverse effects on water purification plants are not expected.
Can be removed mechanically from waste water.
12.4 Additional information
Other harmful effects
none known
General information:
No environmental problems expected if handled and treated in accordance with standard
industrial practices and local regulations where applicable.
13 Disposal considerations
13.1 Product disposal
Recommendation:
After solidification, material can be stored together with domestic waste. Observe
local/state/federal regulations.
13.2 Packaging diposal
Recommendation:
Completely discharge containers (no tear drops, no powder rest, scraped carefully). Containers
may be recycled or re-used. Observe local/state/federal regulations.
14 Transport information
14.1 US DOT & CANADA TDG SURFACE
Valuation....................: Not regulated for transport
14.2 Transport by sea IMDG-Code
Valuation....................: Not regulated for transport
14.3 Air transport ICAO-TI/IATA-DGR
Valuation....................: Not regulated for transport
15 Regulatory information
15.1 U.S. Federal regulations
TSCA inventory status and TSCA information:
This material or its components are listed on or are in compliance with the requirements of the
TSCA Chemical Substance Inventory.
TSCA 12(b) Export Notification:
This material does not contain any TSCA 12(b) regulated chemicals.
CERCLA Regulated Chemicals:
This material does not contain any CERCLA regulated chemicals.
SARA 302 EHS Chemicals:
This material does not contain any SARA extremely hazardous substances.
SARA 311/312 Hazard Class:
This product does not present any SARA 311/312 hazards.
SARA 313 Chemicals:
This material does not contain any SARA 313 chemicals above de minimus levels.
Material Safety Data Sheet
Material: 60004238
HDK® H15
HYDROPHOBIC FUMED SILICA
Version: 1.1 (US) Date of print: 08/06/2008 Date of last alteration: 07/01/2008
Page: 7/8
HAPS (Hazardous Air Pollutants):
This material does not contain any hazardous air pollutants.
15.2 U.S. State regulations
California Proposition 65 Carcinogens:
This material does not contain any chemicals known to the state of California to cause cancer.
California Proposition 65 Reproductive Toxins:
This material does not contain any chemicals known to the state of California to cause
reproductive effects.
Massachusetts Substance List:
This material contains no listed components.
New Jersey Right-to-Know Hazardous Substance List:
This material contains no listed components.
Pennsylvania Right-to-Know Hazardous Substance List:
This material contains no listed components.
15.3 Canadian regulations
This product has been classified in accordance with the Hazard criteria of the CPR and the MSDS
contains all the information required by the CPR.
WHMIS Hazard Classes:
None.
DSL Status:
This material or its components are listed on the Canadian Domestic Substances List.
Non-DSL Chemicals:
This material does not contain any non-DSL chemicals.
Canadian Ingredient Disclosure List:
This material contains no listed components.
15.4 Other international regulations
EU Risk Phrases:
R-Phrase
Description
R-
-
EU Safety Phrases:
S-Phrase
Description
S-
-
Details of international registration status
Listed on or in accordance with the following inventories:
AICS - Australia
EINECS - Europe
TSCA - USA
DSL - Canada
ECL - Korea
PICCS - Philippines
ENCS - Japan
IECSC - China
16 Other information
16.1 Additional information:
This Material Safety Data Sheet (MSDS) meets the requirements of the Federal OSHA Hazard
Communication Standard (29 CFR 1910.1200). This product has been classified according to the
hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all of the
information required by the CPR. This information relates to the specific material designated
Material Safety Data Sheet
Material: 60004238
HDK® H15
HYDROPHOBIC FUMED SILICA
Version: 1.1 (US) Date of print: 08/06/2008 Date of last alteration: 07/01/2008
Page: 8/8
and may not be valid for such material used in combination with any other materials or in any
process. Such information is to the best of our knowledge and belief accurate and reliable as
of the date compiled. However, no representation, warranty or guarantee expressed or implied,
is made as to its accuracy, reliability or completeness. It is the user's responsibility to
satisfy himself as to the suitability and completeness of such information for his own
particular use. We do not accept liability for any loss or damage that may occur from the use
of this information. Nothing herein shall be construed as a recommendation for uses which
infringe valid patents or as extending a license under valid patents. This MSDS provides
selected regulatory information on this product, including its components. This is not intended
to include all regulations. It is the responsibility of the user to know and comply with all
applicable rules, regulations and laws relating to the product being used.
Vertical lines in the left-hand margin indicate changes compared with the previous version.
16.2 Glossary of Terms:
ACGIH - American Conference of Governmental
Industrial Hygienists
DOT - Department of Transportation
hPa - Hectopascals
mPa*s - Milli Pascal-Seconds
OSHA - Occupational Safety and Health Administration
PEL - Permissible Exposure Limit
ppm - Parts per Million
SARA - Superfund Amendments and Reauthorization Act
STEL - Short Term Exposure Limit
TSCA - Toxic Substances Control Act
TWA - Time Weighted Average
WHMIS - Canadian Workplace Hazardous Materials
Identification System
Flash point determination methods
Common name
ASTM D56
Tagliabue (Tag) closed cup
ASTM D92, DIN 51376, ISO 2592
Cleveland open cup
ASTM D93, DIN 51758, ISO 2719
Pensky-Martens closed cup
ASTM D3278, DIN 55680, ISO 3679
Setaflash or Rapid closed cup
DIN 51755
Abel-Pensky closed cup
16.3 Conversion table:
Pressure:
Viscosity:
1 hPa * 0.75 = 1 mm Hg = 1 Torr; 1 bar = 1000 hPa
1 mPa*s = 1 Centipoise (Cp)
Fiche de Données de Sécurité (1907/2006/CE)
Produit: 60004238
HDK® H15
SILICE PYROGENEE HYDROPHOBIQUE
Version : 1.0 (FR) Imprimé le: 06.08.2008 Travaillé le: 21.01.2008
Page: 1/6
1 Identification du produit et de la société
1.1 Description du produit/de la préparation
Nom commercial:
HDK® H15
SILICE PYROGENEE HYDROPHOBIQUE
1.2 Utilisation du produit / de la
préparation:
Industriellement.
Adjuvants pour: Matières synthétiques , Laques ,
Matériaux de construction , produits élastomères ,
Produits cosmétiques .
1.3 Dèsignation de l'entreprise
Fabricant/Fournisseur:
Wacker Chemie AG
Rue/B.P.:
Hanns-Seidel-Platz 4
Nationalité/C.P./Lieu:
D 81737 München
Téléphone:
+498962790
Téléfax:
+498962791770
Informations concernant la fiche de
données de sécurité:
Téléphone
+49/(0) 8677/83-4888
Téléfax
+49/8677/83-5590
E-mail
WLCP-MSDS@wacker.com
1.4 Numéro d'urgence
Appel d'urgence (allemand):
Corps des pompiers
+49/(0) 8677/83-2222
Appel d'urgence (internat.):
National Response Center
+49/(0) 621/60-43333
2 Identification des dangers
2.1 Classification:
CE-R
Identification
R-
-
3 Composition/informations sur les composants
3.1 Caractérisation chimique (substance):
N° CE
N° CAS
Caractérisation chimique
Silice pyrogénée à haute dispersion, hydrophobe, synthétique, amorphe
aux rayons X
4 Premiers secours
4.1 Informations générales:
En cas d'accident ou de malaise, consulter un avis médical (si possible, montrer l'étiquette).
4.2 Après inhalation:
Faire en sorte que la personne dispose d'air frais.
4.3 Après contact avec la peau:
Laver avec beaucoup d'eau pure ou savonneuse. En cas de modification apparente de la peau ou de
douleur, consulter un médecin (si possible, lui montrer l'étiquette ou la fiche de données de
sécurité).
4.4 Après contact avec les yeux:
Rincer aussitôt à grande eau. En cas d'irritation permanente, consulter un avis médical.
4.5 Après ingestion:
Faire boire de l'eau en abondance par petites gorgées. Ne pas provoquer de vomissement.
Fiche de Données de Sécurité (1907/2006/CE)
Produit: 60004238
HDK® H15
SILICE PYROGENEE HYDROPHOBIQUE
Version : 1.0 (FR) Imprimé le: 06.08.2008 Travaillé le: 21.01.2008
Page: 2/6
5 Mesures de lutte contre l'incendie
5.0 Informations générales:
Le produit lui-même ne brûle pas. Les mesures d'extinction porteront sur l'incendie de
proximité.
5.1 Moyens d'extinction appropriés:
néant
5.2 Moyens d'extinction à éviter pour des raisons de sécurité:
néant
5.3 Risques particuliers résultant de l'exposition à la substance/préparation, aux produits de la
combustion, aux gaz produits:
néant
5.4 Equipement de protection spécial:
néant
6 Mesures à prendre en cas de dispersion accidentelle
6.1 Précautions individuelles:
Eviter la formation de poussières. Ne pas respirer les poussières. Porter des équipements de
protection individuelle (voir paragraphe 8).
6.2 Précautions pour la protection de l'environnement:
Couvrir correctement les matériaux renversés pour éviter une propagation due au vent.
6.3 Méthode de nettoyage:
Ramasser par un moyen mécanique et éliminer en respectant la réglementation.
7 Manipulation et stockage
7.1 Manipulation
Précautions à prendre pour une manipulation sans danger:
Éviter la formation de poussière.
Précautions à prendre contre un incendie ou une explosion:
Peut se charger électrostatiquement lors du transport et de la transformation. Eviter
l'accumulation de charges électrostatiques. Veiller à une bonne mise à la terre de tous les
éléments de l'installation. Utiliser un gaz inerte lors du travail avec des liquides
inflammables et explosifs. Eviter les dépôts de poussière ou les enlever régulièrement.
7.2 Stockage
Conditions de sécurité exigées pour le stockage et les containers:
aucun connu
Conditions de stockage pour les matières incompatibles:
néant
Indications supplémentaires sur les conditions de stockage:
Conserver le récipient bien fermé.
8 Contrôle de l'exposition et equipement de protection individuelle
8.1 Valeurs limites d'exposition
Valeurs limites de l'air sur le lieu de travail:
N° CAS
Substance
Type mg/m3
ppm
E/A
fibre/m3
Poussières réputées sans
effet spécifique
TLV_FR 10,0
Fraction
thoracique
Poussières réputées sans
effet spécifique
TLV_FR 5,0
Fraction
alvéolaire
Fiche de Données de Sécurité (1907/2006/CE)
Produit: 60004238
HDK® H15
SILICE PYROGENEE HYDROPHOBIQUE
Version : 1.0 (FR) Imprimé le: 06.08.2008 Travaillé le: 21.01.2008
Page: 3/6
8.2 Limitation et surveillance de l'exposition
8.2.1 Limitation et surveillance de l'exposition sur le lieu de travail.
Mesures générales de protection et d'hygiène:
Ne pas respirer les poussières. Eviter le contact avec les yeux et la peau. L'emploi de crèmes
de protection est recommnandé afin de garantir une protection optimale de la peau. Ne pas
manger, ne pas boire et ne pas fumer pendant l'utilisation.
Equipement de protection individuelle nécessaire
Protection respiratoire:
Lors de la formation de poussières: masque à poussière sans degré de protection .
Protection des mains:
Recommandation: gants en caoutchouc . Gants convenant à une utilisation de durée inférieure à
60 min.
Protection des yeux:
Recommandation: lunettes de protection .
Protection de la corps:
chaussures de travailles, antistatiques .
8.2.2 Limitation et surveillance de l'exposition de l'environnement:
-
9 Propriétés physiques et chimiques
9.1 Indications gènèrales
Etat physique / forme................: solide, poudre
Couleur..............................: blanche
Odeur................................: inodore
9.2 Indications importantes pour la protection de la santé et de l'environnement
aussi bien que pour la sécurité.
Méthode
(67/548/CEE):
Point / intervalle de fusion.........: 1700 °C
Point / intervalle d'ébullition......: néant
Point d'éclair.......................: néant
Température inflammatoire............: néant
Limite inférieure d'explosion........: néant
Limite supérieure d'explosion........: néant
Pression de vapeur...................: néant
Densité..............................: env. 2,2 g/cm³ à 20 °C
Densité relative.....................: 30 - 100 kg/m³
Solubilité dans l'eau................: pratiquement insoluble à 20 °C
Valeur de pH.........................: 3,6 - 5,6
Viscosité (dynamique)................: non utilisable
9.3 Autres informations
Décomposition thermique..............: > 150 °C
10 Stabilité et réactivité
10.0 Informations générales:
Stable dans des conditions d'utilisation normales.
10.1 Conditions à éviter:
aucun(e) connu(e)
10.2 Substances à éviter:
aucun connu
10.3 Produits de décomposition dangereux:
Si les règles de stockage et de manipulation sont respectées: aucun connu .
Fiche de Données de Sécurité (1907/2006/CE)
Produit: 60004238
HDK® H15
SILICE PYROGENEE HYDROPHOBIQUE
Version : 1.0 (FR) Imprimé le: 06.08.2008 Travaillé le: 21.01.2008
Page: 4/6
11 Informations toxicologiques
11.0 Informations générales:
Dans l'état actuel de nos connaissances, aucun risque de dommage si le produit est utilisé dans
les règles de l'art.
11.1 Informations toxicologiques
Toxicité aiguë (valeur LD50/LC50 significative pour la classification):
Exposition
Valeur/gamme de la valeur
Espèce
Source
oral
> 5000 mg/kg
rat (Limit test)
littérature
inhalatif
> 0,477 mg/l/4h
rat (Limit test)
littérature
Symptomes spécifiques sur les bêtes d'après les tests:
Inhalation aiguë: A la concentration maximale pouvant être atteinte, aucune mortalité lors
d'expériences sur l'animal. .
Irritation aiguë:
Exposition
Effet
Espèce/Système de test Source
peau
non irritant
lapin
littérature
oeil
non irritant
lapin
littérature
Informations supplémentaires:
-
De la toxicité subaiguë à chronique:
Informations supplémentaires (subaigu/chron.):
Analyse par analogie avec un produit similaire déjà tudié: Pas d'effects cancérigènes ni
toxiques, d'après des expériences faites sur des animaux. Exposition chronique par inhalation:
D'après des expérimentations animales, réversibilité des altérations au niveau pulmonaire
(inflammation); pas de risque de silicose.
11.2 Expérimentations sur les hommes:
Le produit dessèche la peau. Aucune atteinte à la santé n'a pu être observée en cas de contact
prolongé avec le produit.
11.3 Informations toxicologiques supplémentaires:
-
12 Informations écologiques
12.1 Ecotoxicité
Espèce
Méthode de test
Durée exp. Résultat
Source
Daphnia magna
aigu
24 h
> 10000 mg/l (EC50) littérature
Danio zébré (Brachydanio
rerio)
aigu
96 h
> 10000 mg/l (LC50) littérature
Ne pas s'attendre à un effet nuisible sur les organismes aquatiques.
Réaction dans une station d'épuration (toxicité des bactéries: ralentissement de la respiration
et de la multiplication):
L'expérience actuelle montre qu'il n'y a aucune perturbation à craindre pour les stations
d'épuration. Peut être éliminé mécaniquement des eaux d'égouts.
12.2 Mobilité
Insoluble dans l'eau.
12.3 Persistance et destructibilité
Biodégradabilité / informations supplémentaires:
Substance inorganique: Non applicable.
Informations supplémentaires:
Dépôt par sédimentation.
Fiche de Données de Sécurité (1907/2006/CE)
Produit: 60004238
HDK® H15
SILICE PYROGENEE HYDROPHOBIQUE
Version : 1.0 (FR) Imprimé le: 06.08.2008 Travaillé le: 21.01.2008
Page: 5/6
12.4 Potentiel biologique d'accumulation
Pas d'effets secondaires.
12.5 Autres effets nocifs
aucun connu
12.6 Autres remarques
Informations générales:
Aucune perturbation environnementale n'est à craindre si le produit est manipulé et utilisé
dans les règles de l'art.
13 Considérations relatives à l'élimination
13.1 Produit
Recommandation:
Peut être déposé avec les ordures ménagères, après solidification éventuelle. Respecter la
réglementation locale.
13.2 Emballage contaminé
Recommandation:
Les emballages doivent être vidés (plus de gouttage, plus de ruissellement, curés à la
spatule). L'éventuelle réutilisation des emballages doit être soumise au respect des
réglementations locales ou nationales en vigueur.
13.3 N° du type de déchet (CE):
Le code de nomenclature du Catalogue Européen des Déchets (CED) ne peut pas être déterminé pour
ce produit, car seules les fins d'utilisation par le consommateur permettent une
classification. Au sein de l'UE, le code de nomenclature doit être déterminé en accord avec le
responsable de l'élimination des déchets.
14 Instructions concernant le transport
14.1 Transport par route/chemin de fer GGVSE/ADR et RID
Route ADR:
Estimation...................: produit non dangereux
Chemin de fer RID:
Estimation...................: produit non dangereux
14.2 Navigation fluviale GGVBinsch/ADNR
14.3 Transport maritime GGVmer/IMDG-Code
Estimation...................: produit non dangereux
14.4 Transport aérien ICAO-TI/IATA-DGR
Estimation...................: produit non dangereux
14.5 Transport/autres données
Pour toute information concernant le pt.14:Régul.de transp.:
Service Substances Dangereuses, télécopie : +49/(0) 8677/83-5589, téléphone : +49/(0) 8677/83-
4950
15 Informations règlementaires
15.1 Caractéristiques (CE)
CE-R
Identification
R-
-
CE-S
Identification
S-
-
Fiche de Données de Sécurité (1907/2006/CE)
Produit: 60004238
HDK® H15
SILICE PYROGENEE HYDROPHOBIQUE
Version : 1.0 (FR) Imprimé le: 06.08.2008 Travaillé le: 21.01.2008
Page: 6/6
15.2 Directives nationales:
16 Autres informations
16.1 Produit
Ces données indiquent uniquement les conditions de sécurité du/des produit(s) et s'appuient sur
l'état actuel de nos connaissances. Elles ne dressent pas une liste exhaustive de propriétes
du/des produit(s) décrit(s) dans le sens d'une traité de garantie légal.
Vous tirez les propriétes du/des produit(s) des feuilles de renseignement des produits
respectifs.
16.2 Informations supplémentaires:
Les virgules figurant dans les données numériques désignent les décimales. Les traits verticaux
sur le bord gauche indiquent que des modifications sont intervenues par rapport à la version
précédente.
n.u. = non utilisable n.s. : non subordonné
Indications pour le Statut d'Enrigistrement International
Figure sur les inventaires suivants ou leur est conforme:
AICS - Australia
EINECS - Europe
TSCA - USA
DSL - Canada
ECL - Korea
PICCS - Philippines
ENCS - Japan
IECSC - China